Product Identification

Product ID:TRANS-2-BUTENAL, 0-228
MSDS Date:09/01/1988
FSC:6810
NIIN:00N066041
MSDS Number: CBWFH

Responsible Party
CHEM SERVICE INC
WEST CHESTER, PA 19381
US

Emergency Phone: 215-692-3026

Info Phone: 215-692-3026

Cage: 84898

Contractor
CHEM SERVICE, INC
599 WEST CHESTER, PA 19301-9650 US

Telephone: 610-692-3026

Cage: 8Y898

Ingredients

CROTONALDEHYDE, (E)-; (TRANS-2-BUTENAL) (SARA 302)

CAS: 123-73-9

RTECS: GP9625000

OSHA PEL 2 PPM

ACGIH TLV: 2 PPM

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:LD50:(RAT) 300 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS - AVOID DIRECT PHYSICAL CONTACT! LACHYRMATOR-CAUSES
SEVERE EYE IRRITATION. CAN BE FATAL IF INHALED! MAY BE FATAL IF
SWALLOWED! CAN BE FATAL IF ABSORBED THR OUGH SKIN! CAN CAUSE
EYE/SKIN IRRITATION. DUST &/OR VAPORS CAN CAUSE IRRITATION TO
RESPIRATORY TRACT. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAN BE IRRITATING TO MUCOUS MEMBRANES.
CAN CAUSE EDEMA-SWELLING OF TISSUES. EXTREMELY DESTRUCTIVE OF
MUCOUS MEMBRANES &/OR UPPER RESPIRATORY TRACT. THIS COMPOUND IS
CONSIDERED TO BE TOXIC.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMED . EYES:FLUSH CONTINUOUSLY W/WATER FOR AT
LST 15-20 MINS. SKIN:FLUSH W/WATER FOR 15-20 MINS. IF NO BURNS HAVE
OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. REMOVE & WASH CONTAM
CLTHG. GET MED ATTN IF NEC. INHAL:REMOVE PATIENT TO FRESH AIR.
ADMIN OXYG IF PATIENT IS HAVING DFCLTY BRTHG. IF PATIENT HAS
STOPPED BRTHG ADMIN ARTF RESP. IF PATIENT IS IN CARDIAC ARREST
ADMIN(SUPDAT)

Fire Fighting

Flash Point:55.4F,13.0C
Lower Limits:2.1%
Upper Limits:15.5%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS IS A FLAMMMABLE CHEMICAL.

Accidental Release

Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP & PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATED SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CONTACT W/SKIN, EYES & CLTHG.
KEEP TIGHTLY CLSD & STORE IN A COOL, DRY PLACE. STORE UNDER
NITROGEN & REFRIGERATION. STORE ONLY W/COMPAT CHEMS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HANDLE THIS CHEM/ITS CNTNR. THIS PROD IS FURNISHED FOR LAB USE
ONLY! MFR'S PRODS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRO DS, FOOD ADDITIVES/AS HOUSEHOLD CHEMS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . USE APPROPRIATE OSHA/MSHA SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
LABORATORY.
Supplemental Safety and Health
FIRST AID PROC:CPR. CONTINUE LIFE SUPPORTING MEASURES UNTIL MED
ASSISTANCE HAS ARRIVED. NOTE:AN ANTIDOTE IS A SUBSTANCE INTENDED TO
COUNTERACT EFT OF A POIS. IT SHOULD BE ADMINISTERED ONLY BY
MD/TRAIN ED EMERGENCY PERS. MED ADVICE CAN BE OBTAINED FROM A
POISON CONTROL CENTER. EYE PROT:& FULL LENGTH FACESHIELD .

Chemical Properties

Boiling Pt:B.P. Text:219F,104C
Melt/Freeze Pt:M.P/F.P Text:-106F,-77C
Vapor Pres:30 @ 20C
Spec Gravity:0.853
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE W/CAUSTICS, AMMONIA &/OR AMMONIUM HYDROXIDE, STRONG ACIDS,
STRONG OXIDIZING AGENTS. REACTS W/AMINES.
Stability Condition to Avoid:HANDLE & STORE UNDER NITROGEN. SENSITIVE
TO HEAT.
Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES.
Conditions to Avoid Polymerization:MAY POLYMERIZE UPON STANDING.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER
& SCRUBBER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.